|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
TOTAL POWER INT. TPS40LB SWITCHING MODE 40W LOW COST BOX TYPE POWER SUPPLY KEY FEATURES *Universal input *Built-in EMI filter *LOW COST *Optional constant current change (for single output) APPLICATIONS *Telecommunications *Computer peripherals/Lan & Hub *Test & industrial equipments *Medical instruments *Business machines ELECTRICAL SPECIFICATIONS *Input range-----------90~264 VAC, universal *Frequency------------47~63Hz *Inrush current--------30A typical, Cold start @25,115VAC *Efficiency------------65% ~80% typical at full load *EMI filter------------ FCC Class B conducted, CISPR 22 Class B conducted, EN55022 class B Conducted *Line regulation----- +/- 0.5% typical EMI & EMC (IN PROCESS) *FCC part 15, Class B *CISPR 22 / EN55022, Class B *VCCI ,Class 2 *CE , EN61000-3-2 (Class A) and -3 ; EN61000-4-2, -3 , -4 , -5 , -6 and -11 INPUT SAFETY APPROVAL(IN PROCESS) *UL1950 / c UL *Optional CSA 22.2, LEVEL 3 *TUV EN60950 *Optional UL 2601(EMI Class A) OUTPUT *Maximum power----40W convection(Refer next page) *Hold-up time --------10ms typical at full load and 115 VAC nominal line *Overload protection-Short circuit protection *Overvoltage protection ------------Main output 20% to 40% above nominal output *Ripple/Noise -------- +/- 1% Max. @full load ENVIRONMENTAL *Operating temperature : 0 to 50ambient; derate each output at 2.5% per degree from 50to 70 *Humidity: Operating; non-condensing, 5% to 95% *Vibration : 10~55 Hz at 1G 3 minutes period, 30 minutes along X, Y and Z axis *Storage temperature: -40 to 85 *Temperature coefficient: +/- 0.05% per degree C *MTBF demonstrated: >100,000 hours at full load and 25ambient conditions (Optional +/-0.5% per inquiry) Power Derating Curve 65W 40W Output Power 25W (Watts) 10W 0W 0 10 Natural Convection Cooling 20 30 40 50 60 70 20 W Ambient Temperature( C) TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395 E-mail: sales@total-power.com http://www.total-power.com -1- TOTAL POWER TPS40LB SWITCHING MODE 40W LOW COST BOX TYPE MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT PEAK OUTPUT CURRENT(NOTE1) MINIMUM OUTPUT CURRENT TOTAL REGULATION(NOTE3) RIPPLE & NOISE %P-P(NOTE2) PEAK OUTPUT POWER(NOTE1) SINGLE OUTPUT MODEL SELECTION CHART TPS40LB-10 TPS40LB-11 TPS40LB-12 TPS40LB-13 TPS40LB-14 TPS40LB-15 +5V + 12V +15V +24V +48V +3.3V 10% Typical 10% Typical 10% Typical 10% Typical 10% Typical 10% Typical 8A 3.33A 2.66A 1.66A 0.83A 8A 10.4A 4.33A 3.46A 2.16A 1.08A 10.4A 0A 0A 0A 0A 0A 0A 3% 3% 3% 3% 3% 5% 1% 1% 1% 1% 1% 1.5% 52W Typical 52W Typical 52W Typical 52W Typical 52W Typical 35W Typical DUAL OUTPUT MODEL SELECTION CHART TPS40LB-20 +5V +12 V +5V +24V +5 V -5V +12V -12V +15V -15V +3.3V +12V +5V +48V 10% Typical Fixed 10% Typical Fixed 10% Typical Fixed 10% Typical Fixed 10% Typical Fixed 10% Typical Fixed 10% Typical Fixed 4A 2.5A 6A 0.5A 5A 3A 2A 2A 1.4A 1.4A 8.9A 0.9A 1A 0.8A 7.8A 5.2A 7.8A 1.3A 6.5A 1.3A 4.68A 1.17A 2.21A 2.21A 11.57A 1.17A 13A 0.26A 0.4A 0.25A 0.6A 0.05A 0.5A 0.3A 0.2A 0.2A 0.14A 0.14A 0.89A 0.09A 0.1A 0.08A 5% 5% 5% 5% 5% 5% 5% 5% 5% 10% 5% 10% 5% 10% 1.5% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1.5% 1% 1% 1% 52W Typical 52W Typical 52W Typical 52W Typical 52W Typical 52W Typical 52W Typical TPS40LB-21 TPS40LB-22 TPS40LB-23 TPS40LB-24 TPS40LB-25 TPS40LB-26 TRIPLE OUTPUT MODEL SELECTION CHART + 5V TPS40LB-30 10% Typical Fixed Fixed 10% Typical Fixed Fixed 10% Typical Fixed Fixed 10% Typical Fixed Fixed 10% Typical Fixed Fixed 10% Typical Fixed Fixed 10% Typical Fixed Fixed 10% Typical Fixed Fixed 10% Typical Fixed Fixed 3A 2A 0.5A 3A 2A 0.5A 3A 2A 0.5A 3A 2A 0.5A 3A 1.5A 0.5A 3A 1A 0.5A 1A 2.5A 0.5A 3A 1.5A 0.5A 2A 0.5A 0.6A 3.9A 2.6A 0.65A 3.9A 2.6A 0.65A 3.9A 2.6A 0.65A 3.9A 2.6A 0.65A 3.9A 1.3A 0.65A 3.9A 1.3A 0.65A 9.1A 1.95A 1.04A 3.9A 1.3A 0.65A 9.1A 1.95A 1.04A 0.3A 0.2A 0.05A 0.3A 0.2A 0.05A 0.3A 0.2A 0.05A 0.3A 0.2A 0.05A 0.3A 0.15A 0.05A 0.3A 0.1A 0.05A 0.1A 0.25A 0.05A 0.3A 0.15A 0.05A 0.2A 0.05A 0.06A 5% 5% 10% 5% 5% 10% 5% 5% 10% 5% 5% 10% 5% 5% 10% 5% 5% 10% 5% 5% 10% 5% 5% 10% 5% 5% 10% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1.5% 1% 1% 1% 1% 1% 1.5% 1% 1% 52W Typical 52W Typical 52W Typical 52W Typical 52W Typical 52W Typical 52W Typical 52W Typical 52W Typical +12V -5V + 5V TPS40LB-31 +12V - 12V + 5V TPS40LB-32 +15V -15V +5V TPS40LB-33 +15V -5V + 5V TPS40LB-34 +15V -12V + 5V TPS40LB-35 +24V -12V +5V TPS40LB-36 +12 -12V + 5V TPS40LB-37 +12V +24V +5V TPS40LB-38 +12V +48V NOTES: 1) Peak loads for lasting <30 seconds with a maximum 10% duty cycle are acceptable. Please contact us if need special peak load. 2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth, 0.1F and 47F Cap. on outputs. 3) Loading test conditions are set for all outputs at minimum, middle and maximum of loads. Special cross loading requirement is welcomed. 4) Detailed engineering specification of each model is available for inquiry. 5) Special output voltage/current inquiry is welcomed. 6) Specifications subject to change without notice. TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395 E-mail: sales@total-power.com http://www.total-power.com -2- |
Price & Availability of TPS40LB-38 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |